SIPLUS CPU 416-3/416-3 PN/DP

功能

  • Block protection:
    A password concept protects the user program from unauthorized access.

  • Integral HMI services:
    The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.

  • Integrated communications functions:

    • PG/OP communication

    • Shared data communication

    • S7 standard communication

    • S7 communication

  • Firmware update using network

  • 微信图片_20200831222130.jpg

CPU 416-3 PN/DP additional:

  • Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)

  • Distributed intelligence in Component Based Automation (CBA) on PROFINET

  • Additional diagnostic options with integrated web server

Parameterizable attributes

The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

  • Multi-point interface MPI:

    • Definition of station addresses.

    • Startup/cycle behavior

    • Stipulation of the maximum cycle time and communications load

  • Address assignment:
    Addressing of I/O modules.

  • Retentive ranges:
    Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.

  • Size of the process image, local data.

  • Length of the diagnostics buffer

  • Protection level:
    Definition of access authorization for program and data

  • System diagnostics:
    Definition of the handling and scope of diagnostic messages

  • Timed interrupts:
    Setting of periodicity

  • 3bd033d55d55fddc5578cc0a98a3f0c - 副本.jpg

CPU 416-3 PN/DP additional:

  • PROFINET interface

  • Parameterization of time synchronization using NTP procedure

Indication and information functions
  • Status and error indicators:
    LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example

  • Test functions:
    The programming device can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components

  • Information functions:
    The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories

概述

高端性能范围内的高性能 CPU

  • 适用于对性能要求很高的工厂

  • CPU 416-3 PN/DP 中集成了 PROFINET 功能

注:

SIPLUS extreme 产品基于 SIMATIC 标准产品。此处列出的内容来自相关的标准产品。添加了特定 SIPLUS extreme 信息

设计

Both CPUs are equipped with the following:

  • Powerful processor:
    The CPUs achieve instruction execution times as low as 0.03 µs per binary instruction.

  • CPU 416-2: 5.6 MB RAM (of which 2.8 MB each for program and data);
    CPU 416-3: 11.2 MB RAM (of which 5.6 MB each for program and data);
    CPU 416-3 PN/DP: 11.2 MB RAM (of which 5.6 MB each for program and data);
    fast RAM for parts of the user program relevant to execution.

  • Flexible expansion:
    Up to 262144 digital and 16384 analog inputs/outputs.

  • Multi-point interface MPI:
    With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.

  • Mode selector switch:
    Designed as toggle switch.

  • Diagnostics buffer:
    The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.

  • Real-time clock:
    The date and time are appended to diagnostic messages of the CPU.

  • Memory card:
    For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available

  • Combined MPI/DP interface and integrated PROFIBUS DP interface (CPU 416-2 and CPU 416-3):
    The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming).
    Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.

CPU 416-3 and CPU 416-3 PN/DP also include:

  • A module slot:
    An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module.

CPU 416-3 PN/DP additionally includes:

  • PROFINET interface with 2 ports (switch):

    • PROFINET I/O, 256 IO devices connectable

    • PROFINET CBA